Basic Info.
After-sales Service
Free Maintenance During The Warranty Period
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas
Application
Industrial Production
Type
Ultrasonic Flow Meter
Measuring Principle
Mechanics
Measurement Object
Closed Pipeline
Certification
ANS, CE, ISO
Liquid Types
Virtually All Liquids
Power Supply
AC: 110V/220V, or DC :8VDC-36VDC
Product Name
Ultrasonic Flowmeter
Maximum Flow Rate
64m/S (Velocity Resolution 0.001m/S)
Measuring Medium
Water, Sewage, Sea Water, Sprinkling, etc.
Fluid Temperature
0~160deg
Output Signal
Output Optional 4~20mA, Pulse, Oci, Frequency, RS4
Ingress Protection
Main Unit:IP67; Transducers:IP68
Display
LCD Digital Display
Transport Package
Aluminum Alloy Box
Specification
DN15-DN6000
Product Description
TUF-2000P-TM-1 Ultrasonic Flowmeter Flow Meter with Built-in Printer and TM-1 Standard Transducer Range DN50mm-DN700mm
Easy installation, no maintenance is needed. |
High accuracy within ±1% |
High protection class: Main unit:IP67; Transducers:IP68 |
GPRS-based design, multiple signal output, achieve remote monitoring. |
Achieve heat measurement by connecting 3-wired heat transducers PT100. |
Product Description
Display | 2*16 lines display |
Keypad | 4*4 keys |
Power supply | DC8~36V or AC85~264V |
Signal outputs | 4~20mA, OCT, relay, RS485(support MODBUS) |
Signal intputs | 3 WAY 4-20mA |
Data storage | SD card |
TUF-200B Flowmeter can be virtually applied to a wide range of long-term online measurement. Convertor protection class IP67,transducer protection class IP98.
A variety of liquid applications can be accommodated: ultra-pure liquids ,portable water,chemicals,raw sweage,reclaimed watere,cooling water,river water,plant.etc.
Product Parameters
Convertor | Principle | Transit-time ultrasonic flowmeter |
Accuracy | ±1% |
Display | 2x20 character LCD with backlight, support the language of Chinese, English, Italy, Turkish |
Signal output | 1way 4-20mA output, electric resistance 0-1K, accuracy0.1% |
1 way OCT pulse output(Pulse width-1000ms, default is 200ms)) |
1 way Relay output |
Signal input | 3 way 4-20mA input, accuracy 0.1%, acquisition signal such as temperature, press and liquid level |
Connect the temperature transducer P100, can finish the heat/energy measurement. |
Data Interface | Insulate Rs485 serial interface, upgrade the flowmeter software by computer, support the MODBUS. |
Special Cable | Twisted-pair cable, generally, the length under 50 meters, select the Rs485, transmission distance can over 1000m |
Pipe Installation Condition | Pipe material | Steel, stainless steel, cast iron, copper, cement pipe, PVC, Aluminum, glass steel product, liner is allowed |
Pipe diameter | 25-6000mm |
Straight pipe | Transducer installation should be satisfied: upstream10D, downstream5D, 30D from the pump. |
Measuring Medium | Type of liquid | Single liquid can transmit sound wave; such as water (hot water ,chilled water, city water, sea water, waste water, etc); sewage with small particle con tent, oil(curde oil, lubricating oil, diesel oil, fuel oil, etc); chemicals(alcohol, etc); plant effluent; beverage; Ultra-pure liquids, etc |
Temperature | -30-160ºC |
Turbidity | No more than 10000ppm and less bubble |
Flow rate | 0-±7m/s |
Temperature | Convertor; -20-60ºC; Flow Transducer: -30-160ºC |
Humidity | Convertor: 855RH; Flow Transducer: can measure under water, water depth≤2m |
Working Environment | Temperature | Convertor; -20-60ºC; Flow Transducer: -30-160ºC |
Humidity | Convertor: 855RH; Flow Transducer: can measure under water, water depth≤2m |
Power Supply | DC8-36V or AC85-264V(Optional) |
Power Consumption | 1.5W |
Dimension | 132*150*85mm(convertor) |
Sensor selection
Scope of application
Don't worry . In order to help you get the exact model, please offer the following necessary information |
1.The pipe size is DN___mm |
2.Temperature is _____ °C |
3.The material of the pipe is _____ |
4.Power Supply___ |
5.Other requirements :_____ |
Company Profile
Packaging & Shipping
FAQ
1.Are you a trade company or a manufacturer?
Kaifeng Hollysys Meter Co., Ltd has been a professional manufacturer for over 10 years to undertake design and processing of all types of flow meter to provide production service and technical support for customers.
2.What to do if I have any other specifications for the current?
If you have any different requirements,just contact us and we will meet you.
3.If I need a sample for pretest, do you sale sample for this inquiry?
Yes, we can sale sample for pretest. If you need this service, please contact us and we will give you a quotation.
4.Can you produce the products according to my own drawings?
Yes, we can do OEM according to your requirement.
Address:
Northwest of The Intersection of Longhai 2nd Road and Nine Street, Longting District, Kaifeng, Henan, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Instruments & Meters
Management System Certification:
ISO 9001
Company Introduction:
Different kinds of products are available in our company. We′re pleased to get your Inquiry and we will reply you as soon as possible. We stick to the principle of "quality first, service first, continuous improvement and innovation to meet the customers" for the management and "zero defect, zero complaints" as the quality objective.