Basic Info.
After-sales Service
Lifelong Aftersales
Main Application
Water, Wastewater, Corrosive Liquid/Gas
Type
Electromagnetic Flow Meter
Certification
GB, CE, ISO, Sil, MID
Product Name
Electromagnetic Flow Meter
Connection
Flange Connection
Liner Material
PTFE, F46, Rubber, Polyurethane
Accuracy Grade
0.5%, 0.3%, 0.2%
Protection Grade
IP65, IP67, IP68
Signal Output
4-20mA, Pulse
Communication
RS485, RS232, Modbus, Hart, GPRS
Trademark
Kaifeng Hollysys
Transport Package
Paper Carton or Plywood Box
Specification
carbon steel, SS304, SS316
Product Description
Product Description
Electromagnetic flowmeter working principle
Faraday's Laws of induction form the basis for the magnetic water flow meter which states that a voltage is generated in a conductor as it moves through a magnetic field.
This principle is applied to a conductive fluid which flows through the meter tube perpendicular to the direction of the magnetic field (see Schematic).
UE ~ B · D ·V
The voltage induced in the fluid is measured by two electrodes located diametrically opposite to each other.
This signal voltage UE is proportional to the magnetic induction B, the electrode spacing D and the average flow velocity v. Noting that the magnetic induction B and the electrode spacing D are constant values indicates that a proportionality exists between the signal voltage EU and the average flow velocity v. From the equation for calculating the volume flowrate* )UE ~ qv, it follows that the signal voltage is linear and proportional to the volumetric flowrate.
Product Parameters
Main Features
1). With simple structure ,the flow meter is of high reliability.
2). The wide range of the nominal bore is suitable for all the pipe size between DN6 and DN3000.
3). Measurement is independent of fluid density ,viscosity ,humidity ,temperature pressure and conductivity.
4). The sensor with advanced processing technology and liquid airproof is of long natural life and of nice resistance to shaking leakage.It guarantees the instrument good precision and stability .
Technical specifications of electromagnetic flowmeter
Item | The Specifications of electromagnetic flowmeter |
Installation Type | Split/remote, integrated/compact |
Measuring fluid | conductive fluid and slurry |
Caliber | DN6-DN3000 |
End connection | Flange, threaded, clamping, insertion type, etc. |
Electrode materials | Mo2Ti HC HB Pt Ta Ti |
Flange standard | GB, DIN, JIS, EN, SABS, etc. |
Lining Material | PTFE, PFA (resistance to negative pressure), chloroprene rubber, polyurethane, hard rubber (optional conductive ground rubber), F46 |
Electrode Type | Standard type 316L, scraper-type (DN ≥ 50) |
Dielectric conductivity | > 5μs/cm (water> 20μs/cm) |
Accuracy grade | ±0.5% RS. |
Flow Range | 0-10m/s |
Maximum temperature of medium | For rubber liner ≤ 80 °C, for PTFE liner ≤ 120°C |
Ambient temperature | -20 - +60 |
Working pressure | 0.6Mpa-4.0Mpa, the special high rpressure is available |
Protection Level | IP65, IP67, IP68 (optional) |
Power | 220VAC(85~250 voltage) 24VDC(11~40 voltage) |
Display | Forward and backward instantaneous flowrate, total flow, velocity, flowrate percentage with back light |
Output | 4-20mA current output ,0-1kHz frequency output, pulse output per unit volume |
Communication | RS485 @Modbus, RS232@Modbus, HART, Profibus, GPRS, etc. |
Company Profile
Kaifeng Hollysys Industrial Instrument Co., Ltd. is a high-tech enterprise commit into research and development, manufacture of flow instruments. Located at the base of China flow instrument, Kaifeng, we have full access to gain the most advanced technology in field. All these make us full of confidence to provide products with international standard.
Certifications
Our Advantages
For Before-sales advise
In order to recommend you the most suitable our electromagnetic sensor , please show us following necessary information according to your practical situation.
1.What is your measuring medium ? Conductive liquid or slurry
2.Working pipe size? 6-3000mm
3.Install type? Flange ,Inserted,Threaded, Clamped.
4.Electrode material? SS316,HB,HC,Ta,Ti,Pt
5.Liner material? PTFE,rubber,neoprene,FEP,PFA,polyrethane
6.Communication mode? RS485, Modbus, RS232 ,Modbus, HART, Profibus, GPRS, others
After-sales service
We promise to deliver the following after-sales service:
1.Warranty: The warranty period is 12 months starting from the shipping date;
2. Customers will enjoy free repair services for failures found within the warranty due to manufacturing quality;
3. For on-site services not arising from manufacturing quality, we shall charge a certain service fee at our discretion based on actual charges incurred such as travel expense;
4. We provide paid repair services for meter damages not arising from manufacturing quality issues or meter damages not within the scope of warranty.
FAQ
Q1. Can you accept OEM service ?
A:We professional provide OEM service for electromagnetic flow meter.
Q2. Could I get samples?
A:Yes,we can arrange production and delivery as soon as possible to help you get the sample.
Q3. How about the quality of the magnetic flow meter?
A:Every magnetic flow meter is five-pionted calibrated in flow meter calibration equipment,we'd provide factory certification test to you.
Q4. Could you provide me the shortest lead time?
A:Generally delivery is 2-3 working days after received payment,if urgently required,we will try our best to satisfy you.
Q5. Could I visit your factory?
A:Welcome to visit us,we will guide your visit in our factory.
Q6. How can I get the quotation?
Q7.What is your MOQ?
A: To start our cooperation, sample order is acceptable.
Installation Instructions
1. How to lift, move electromagnetic flow meter?
2. How to ensure electromagnetic flowmeter earthing grounding?
3. Electromagnetic flowmeter upstream and downstream requirements